Book Now

Call Now

Contact Us

Book Now

Doylestown PA Heating Air Conditioning

Rated 4.9 out of 996 reviews

Chud has provided air conditioning, heating, water heater, air quality and duct cleaning services to the residents of Doylestown, PA and the surrounding areas since 1970! We’re committed to providing first class air conditioning service to all of our clients.

We’re the AC experts. But don’t take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby Doylestown, PA heating and air company that specializes in air quality and duct cleaning.

Local Reviews
for Doylestown, PA

Chud Air Conditioning & Heating Rated 4.8 out of 5 stars based on 13 customer reviews
Mobile Tools for Contractors and Service Professionals Powered by Nearby Now


Map of Doylestown, PA

Good professional service




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you Charles!


Map of Doylestown, PA

Great service




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

Margarita, thank you for the 5 star review!


Map of Doylestown, PA

Professional reliable servicea and advice




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you Charles!


Map of Doylestown, PA

Great explanation, price and thorough install.




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you James & Rochelle!


Map of Doylestown, PA

O




Review of Chud Air Conditioning & Heating

0


Response from Chud Air Conditioning & Heating:

5 stars, thank you Charles!


Map of Doylestown, PA

First time customer




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

We’re sorry your experience didn’t match your expectations. Please give us a call at 215-659-4343 to discuss what we could have done better.


Map of Doylestown, PA

very satisfactory service




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you Charles!


Map of Doylestown, PA

Administrative




Review of Chud Air Conditioning & Heating

Great Service!!


Response from Chud Air Conditioning & Heating:

Thanks so much for the 5 star review Jeffery. The Chud team appreciates it!


Map of Doylestown, PA

Always good service




Review of Chud Air Conditioning & Heating

Chud provides excellent, honest service.


Response from Chud Air Conditioning & Heating:

Thank you for the kind words and 5 star review. The Chud team appreciates it!


Map of Doylestown, PA

He did very. Well




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you Kenneth!


Good service




Review of Chud Air Conditioning & Heating

The technician wa polite and helpful


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Kenneth & Susan, everyone at Chud appreciates it!


Fast response




Review of Chud Air Conditioning & Heating

Came out quickly to address water heater issue.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Esther. Everyone at Chud appreciates it!


I am pleased




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

Hi Barry & Joan, so glad you were pleased. Thank you for the 5 star review!!


Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 3 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is due at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!

Near Old Oak Rd, Doylestown, PA 18902
Keith R.

Keith R.

Performed first floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!

Near Glen Dr, Doylestown, PA 18901
Keith R.

Keith R.

Performed an air duct cleaning and sanitation on a 4 bedroom 2 system house. All vents and ductwork are clear of dust and debris at this time. Both systems are functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business! Both specialty filters need to be replaced. Size is 20”x25”x4” Customer paid in advance. Pictures of the water heater included.

Near Hancock Ln, Doylestown, PA 18902
Paul T.

Paul T.

Replace the condenser fan motor for an ICP condensing unit. Model #n4a318akc100, serial #E140621066. The current motor is pulling a high amp draw and is seized. Includes new capacitor if needed. Quoted at $935. 8/4/22-PT- Turned power off to the system at the thermostat and disconnect. I removed the old condenser fan motor. I installed a new condenser fan motor and used the existing fan blades since the repair did not include a blade. Connected all the proper wiring and installed a new 30+5 capacitor. I turned the power back on and called for air conditioning. The system started right up without any issues. Condenser amp draws are now .40 for the fan and 5.8 for the compressor. The temperature split is at a 20.

Near Jacob Stout Rd, Doylestown, PA 18902
Frank B.

Frank B.

Came out to replace the air filters for 3 rooftop systems. The 2 original rooftop units take 2-20x30x2 air filters each and the new Rheem/RUUD unit takes 2-16x25x1 air filters. All 3 systems seem to be operating properly at this time. Next service will be for heating/heat pump maintenance and filter change. No charge due to commercial agreement. No charge due to commercial agreement.

Near W Oakland Ave, Doylestown, PA 18901
Paul T.

Paul T.

Came out today for a lock out issue on a Weil-McLain tankless boiler/hwh. Upon inspection I found that the code was for a maintenance reminder. I reset the maintenance reminder and installed a new maintenance kit (wm97+) for the system. This includes seal gaskets , igniter, flame sensor and other parts . All required parts have been replaced. I tested the system by calling for heat and then calling for hot water. Performed a combustion analysis test and received the following readings 02 is at 12%, co is at 8ppm. The system is operating properly at this time. Bill out due to no service at location.

Near Landisville Rd, Doylestown, PA 18902
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!

Near Bittersweet Dr, Doylestown, PA 18901
Paul T.

Paul T.

Came out today to investigate a puffing noise coming from a Weil-McLain boiler/ hot water heater. Upon arrival I called for heat to I could hear the noise for myself. The system started heating it then hit the temp limit and then shut down. I tried to recreate the noise with calling for hot water but I received the same results. I attempted to call for heat and hot water separately for a second time and still no noise. I powered the system down and inspected the igniter. The igniter is in good condition and is operating properly. At this time I am unable to recreate the noise the homeowner is hearing. I tested the system, checked the igniter, checked the trap, water pressure is at 15 psi, limit is set for 180 and all circulator pumps are operating properly. I cannot find any issues with the system. The invoice will have to be billed out due to no service at the home.

Near Landisville Rd, Doylestown, PA 18902
Paul T.

Paul T.

Performed preventative maintenance for a York system model #Ckl3610, serial #0103490560. The evaporator coil’s are clean and in fair condition. Tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Homeowner recently replaced the air filter size 16x24x1. Checked all electrical components needed for air conditioning to ensure that they are clean and in good condition. The blower motor amp draw is within normal range. The temperature split is at a 20. The condenser coil’s are clean and in fair condition. The amp draws for the condenser are .74 for the fan and 8.3 for the compressor. The refrigerant pressures are within normal range. The system is operating properly at this time however the system is extremely old roughly 22 years old. The system should be updated. Chud cannot guarantee that there will not be any issues in the future due to the age and lack of maintenance. As of today the Ac is operating properly.

Near Miladies Ln, Doylestown, PA 18902
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!

Near Miladies Ln, Doylestown, PA 18902
Sebastian R.

Sebastian R.

Customer replaced 16x25x1 air filter prior to us coming out. Checked evaporator coil pan and condensate pump for proper drainage. Temperature split is at 4° with a supply air temperature of 67°. This unit does not have a proper refrigerant charge. Customer was quoted for 3 pounds of R410 refrigerant and easy seal and dye. Work was performed and the subcool is now at 10 which is what it is rated for. This unit now has the proper refrigerant charge. System is operating properly at this time and is ready for the upcoming season.

Near W Blossom Dr, Doylestown, PA 18902
Sebastian R.

Sebastian R.

Performed preventative maintenance on Lennox AC system. Replaced 17x19x1 Air filter provided by the customer. Tested condensate pump and evaporator coil pan for proper drainage. Temperature split is at 20° with a supply air temperature of 50°. This unit has the proper refrigerant charge. Compressor-6.8 Condenser fan motor-0.7 . Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the season.

Near School Hill Dr, Doylestown, PA 18901
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 3 bedroom 2 system house. All vents and ductwork are clear of dust and debris at this time. Both systems are functioning properly at this time. Recommend air duct cleaning every 3-4 years. Thank you for your business!

Near W Blossom Dr, Doylestown, PA 18902
Sebastian R.

Sebastian R.

Performed preventative maintenance on 2 Airquest AC systems. (Attic)MERV 11 16x25x5 Filter was replaced by customer prior to us coming out. Tested condensate line and evaporator coil pan for proper drainage. Temperature split is at 20°. This unit has an accurate refrigerant charge. Compressor-3.5VRLA Condenser fan motor- 0.3 FLA. Both of these readings are within the amperage rating for this unit. System is operating properly properly at this time. (Basement ) MERV 11 16x25x5 air filter was replaced by customer prior to us coming out. Tested evaporator coil pan for proper drainage. Temperature split is at 20° with a supply air temperature of 48°. This unit has the proper refrigerant charge. Compressor- 4.2 RLA Condenser fan motor- 0.5 FLA. Both of these readings are within the amperage rating for this unit. Both systems are operating properly at this time and are ready for the upcoming season. Filter- MERV 11 16x25x5

Near Jacob Stout Rd, Doylestown, PA 18902
Paul A.

Paul A.

Found a leaking relief valve on newly installed Weil McLain Ultra 155 style boiler. The new equipment was installed reusing all external trim kit items including expansion tank and water fill. Replaced the relief valve under warranty on site. Tested system for proper operation. Observed (1) lockout initially on start up, which may be related to draining the expansion tank while the system was running. Adjusted boiler setpoint back to 200 degrees, target temp is 180 degrees. Observed operation to verify no lockouts. Boiler was able to be isolated for the repair, however the expansion tank needed to be drained and (1) radiant loop purged of air. System is currently operating properly.

Near W Court St, Doylestown, PA 18901
Paul T.

Paul T.

Replaced 4 20x30x2 air filters on the old systems and 2 16x25x1 air filters on the new RUUD system.

Near W Oakland Ave, Doylestown, PA 18901
Keith R.

Keith R.

Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years. Thank you for your business!

Near Diane Way, Doylestown, PA 18902
Paul A.

Paul A.

Investigated areas on 2nd floor of home, specifically master bedroom for not keeping up with setpoint. Verified that the zone is working. The zone does not need to be purged as the piping is extremely hot. At this point we are attributing this issue to the bitter cold temperatures yesterday and today. Finned tube baseboard also can have a lot of heat loss as they are mounted directly to outside wall locations. This is also a historic home built in the 1800's, so it can be common to have cold spots in the home depending on outdoor conditions. The boiler system is currently operating per manufacturer specifications. I advised the homeowner of the conditions and he will continue to monitor the situation.

Near W Court St, Doylestown, PA 18901
Paul A.

Paul A.

Performed Air Duct Cleaning Service on a 1 system, 3 bedroom unit. System was just the air handler as the homeowner stated they have a boiler that's used for the heat in the home. All duct work vents are clear of dust and debris as of this time. System is working properly and ready for the season!

Near Belmont Ave, Doylestown, PA 18901
Frank B.

Frank B.

Customer called for no heat. Upon inspection I found the system in normal idle mode but as I adjusted with the thermostat I found the Honeywell T6 setup with an auto change over mode. This mode is not designed for this standard setup. Turned it off and tested the system upon completion. If this happens to not fix the issue the thermostat is the only other possibility. The Honeywell T6 thermostat would need to be replaced next.

Near Morrison Way, Doylestown, PA 18902
Frank B.

Frank B.

Performed preventative maintenance for standard gas furnace. Filter was replaced in the spring last year. It's not due till spring 2022. Inspected all the electrical components. Confirmed proper high and low voltages. Cleaned the flame sensor, burners and burner compartment. Tested the amp draw of the blower and inducer. Both are operating properly within the manufacturer specs. Performed a combustion analysis on the furnace. System is operating at 83.3% efficiency with a CO level of 17ppm. System is operating properly at this time.

Near Wellington Rd, Doylestown, PA 18902
Frank B.

Frank B.

Performed preventative maintenance for high efficiency furnace. Cleaned the burners and flame sensor. Customer replaces aprilaire 413 specialty filter. Inspected all electrical components. Inspected the gas piping, exhaust and air intake. Inspected the condensate drain piping. Inspected all tubing coming from collector box of any blockages. No blockages at this time. Inspected the bypass humidifier operation to confirm it is working properly. Customer supplies the #35 water panel for the humidifier. Performed a combustion analysis on the furnace. System is operating at 95% efficiency with a CO level of 8ppm. Customer also has a Reme-Halo air purifier that he replaced the cell I recommended last year. Reme was still not working after cell replacement. Found that the ballast is no good and needs replacing. Reme is 3 years old and is still under factory warranty. Customer said he will follow up with Reme about the matter. System is operating properly at this time.

Near Honey Hollow Rd, Doylestown, PA 18902
Paul T.

Paul T.

Performed preventative maintenance for a Lennox furnace. I observed the system starting normally. I took a combustion analysis test and got the following readings, o2 is at 9%, co is at 9ppm and the system is operating at 83% efficiency. I observed the system shut down normally. I removed and cleaned carbon off of the flame sensor. Cleaned out the burners and burner box. Checked all electrical components needed for heating. Replaced the air filter 14x25x1. The system is operating properly at this time. Please send a reminder for the repair agreement for next year.

Near Point Pleasant Pike, Doylestown, PA 18902
Paul A.

Paul A.

Replaced Taco 0015 circulator cartridge (pump) that is internal to the boiler. Some draining and purging was required. Contacted Tony Calderone from Weil McLain and he guided me through the contractor settings to set up DHW priority and verified all settings are correct. Verified the boiler pump is operating properly and both house pumps are operating properly.

Near Landisville Rd, Doylestown, PA 18902
Matthew M.

Matthew M.

Completed Weil McLain ultra boiler replacement. Adapted to existing electrical, plumbing, venting, gas line, and drain. Bled out loops that were air bound. Cycled and tested, system working properly at this time.

Near W Court St, Doylestown, PA 18901
  • HomeAdvisor Top Rated Service
  • HomeAdvisor Elite Service Award - Chud Air-Conditioning, Heating, Refrigeration Co., Inc.
100% Customer Satisfaction Guaranteed
Schedule Service Today
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Please Upload Your Photos
Contact and Service Location...
You and Your Service Location
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon
Back Next