Book Now

Call Now

Contact Us

Book Now

Dresher PA Heating Air Conditioning

Rated 4.9 out of 1136 reviews

Chud has provided air conditioning, heating, water heater, air quality and duct cleaning services to the residents of Dresher, PA and the surrounding areas since 1970! We're committed to providing first class air conditioning service to all of our clients.

How much does it cost to replace an HVAC system near Dresher?

The cost to replace an HVAC system near Dresher and other areas of Greater Philadelphia averages $7,000, with a range of $5,000 to $10,000

Some of the primary factors that can influence the price are:

  • Size of the house (and size of the system required).
  • The complexity of the installation. For example, whether the new unit also requires new ductwork.
  • Brand and type of system. High-end brands will usually cost more.

Dresher homeowners with questions about their HVAC system can contact the expert team at Chud today for trusted advice.

How much does HVAC repair usually cost near Dresher?

An HVAC repair near Dresher or other areas of Philadelphia usually costs between $150 and $300. At the same time, note that repair or replacement costs for major components like coils can be much more costly.

The total cost of the problem depends on factors like:

  • The time it takes to complete the repair.
  • Prices of any new components or parts needed.
  • The system’s make, model and age.

Most companies will charge a diagnosis fee to have an HVAC tech come out and look at the problem. 

If you see signs that the HVAC system in your Dresher home may be having issues, contact the trusted service team at Chud, and we can send out a technician right away.

Can an air conditioning system leak be fixed?

In many cases, no, an air conditioning refrigerant leak cannot be fixed, at least not as a long-term solution. Usually, a refrigerant leak is discovered when a system doesn’t seem to be cooling well and a homeowner calls an HVAC technician to test the system. 

Leaks are usually caused by a multitude of pinhole-sized leaks in a coil, especially in older systems. An HVAC tech can sometimes try to charge the refrigerant or seal the coils, but these fixes often don’t last long. Sometimes, a homeowner will have to weigh the pros and cons of repairing or replacing the system.

It’s essential to work with an HVAC company that you trust if you are considering a major repair like a refrigerant leak. Homeowners in Dresher, PA, can contact the local experts at Chud for HVAC repairs, maintenance and replacement.

We're the AC experts. But don't take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby Dresher, PA heating and air company that specializes in air quality and duct cleaning.

Local Reviews
for Dresher, PA

Chud Air Conditioning & Heating Rated 4.9 out of 5 stars based on 52 customer reviews

Our Reviews by City

Rydal, PA (13)


Map of Dresher, PA 19025

Detailed Diagnosis




Review of Chud Air Conditioning & Heating

Chud did an excellent job of checking out furnace and explaining status of furnace operation

DresherPA19025 40.1325-75.165

Response from Chud Air Conditioning & Heating:

Mark, thank you for the 5 star review, we are grateful that you chose Chud.


Map of Dresher, PA 19025

Great Service




Review of Chud Air Conditioning & Heating

Paul T. was very helpful when he was here. He explained everything in easy terms.

DresherPA19025 40.1325-75.16

Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Francis & Miriam. It truly means a lot to the Chud team!


Map of Dresher, PA 19025

Great service




Review of Chud Air Conditioning & Heating

DresherPA19025 40.13-75.1625

Response from Chud Air Conditioning & Heating:

5 stars, thank you Masha!


Map of Dresher, PA 19025

160 High Point Avenue




Review of Chud Air Conditioning & Heating

Great job

DresherPA19025 40.1375-75.1625

Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Peter & Jackie. It truly means a lot to the Chud team!


Map of Dresher, PA 19025

Frank is so competent, knowledgeable with excellent communication skills & a respectful kind way about him.




Review of Chud Air Conditioning & Heating

Frank Breen

DresherPA19025 40.1575-75.175

Response from Chud Air Conditioning & Heating:

Charles & Joanne, we’ll make sure to pass your kind words along to Frank, who we know will be delighted to read your comments.


Map of Dresher, PA 19025

Excellent service and explanation of services performed




Review of Chud Air Conditioning & Heating

Easy, efficient

DresherPA19025 40.1525-75.1525

Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you, Marc & Shelley.


Map of Dresher, PA 19025

Excellent service




Review of Chud Air Conditioning & Heating

Paul is helpful, patient, and cheerful.

DresherPA19025 40.15-75.155

Response from Chud Air Conditioning & Heating:

Jan, thank you for the 5 star review, we are grateful that you chose Chud.


Map of Dresher, PA 19025

Thorough report




Review of Chud Air Conditioning & Heating

Paul did our fall service and gave us a detailed report afterwards.

DresherPA19025 40.13-75.165

Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Ruth & Jules. It truly means a lot to the Chud team!


Map of Dresher, PA 19025

Excellent service




Review of Chud Air Conditioning & Heating

Helpful,professional job

DresherPA19025 40.1375-75.1575

Response from Chud Air Conditioning & Heating:

5 stars, thank you Sue!


Map of Dresher, PA 19025

great service, answered all my questions , patient and kind. the best service tech I’ve had to my home !




Review of Chud Air Conditioning & Heating

DresherPA19025 40.1375-75.1625

Response from Chud Air Conditioning & Heating:

Lizanne, we’ll make sure to pass your kind words along to Keith, who we know will be delighted to read your comments. Thank you for choosing Chud!


Professional job




Review of Chud Air Conditioning & Heating

Great experience

DresherPA19025 40.1375-75.1625

Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Peter & Jackie.


Puglia




Review of Chud Air Conditioning & Heating

Great service, personable young man.

DresherPA19025 40.1575-75.175

Response from Chud Air Conditioning & Heating:

Charles & Joanne thank you for the 5 star review, we are grateful that you chose Chud.


clean, on time, effective




Review of Chud Air Conditioning & Heating

I have worked with Chud for decades and their prices are competitive. Their communication is always excellent, their services are clean and efficient, and the personnel are always polite and easy to talk to. Have not found reason to ever look anywhere else.

DresherPA19025 40.1525-75.1775

Response from Chud Air Conditioning & Heating:

Alan, we appreciate the good review. Chud works hard to create a good experience and reviews like this make it all worth it!


Great Service




Review of Chud Air Conditioning & Heating

DresherPA19025 40.1325-75.16

Response from Chud Air Conditioning & Heating:

5 stars, thank you Francis & Miriam!


Chud is efficient




Review of Chud Air Conditioning & Heating

Been keeping up the maintenance for years and have had no issues. Definitely worth the piece of mind.

DresherPA19025 40.1525-75.1525

Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Marc & Shelley, everyone at Chud appreciates it!


Great Service




Review of Chud Air Conditioning & Heating

Sebastian was competent & personable.

DresherPA19025 40.1575-75.175

Response from Chud Air Conditioning & Heating:

Charles & Joanne, thank you for the kind words and 5 star review!


Great service, on time, professional, neat




Review of Chud Air Conditioning & Heating

DresherPA19025 40.1575-75.17

Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Jeff & Jane.


Home Reno cleaning




Review of Chud Air Conditioning & Heating

DresherPA19025 40.1375-75.1575

Response from Chud Air Conditioning & Heating:

We always strive for 5, please give us a call at 215-659-4343 to let us know what we could have done to get that 5th star.


Great Service




Review of Chud Air Conditioning & Heating

Frank is very professional & not only expert at his profession, but caring & kind in his demeanor.

DresherPA19025 40.1575-75.175

Response from Chud Air Conditioning & Heating:

Thank you for the kind words and 5 star review! The Chud team appreciates it.


Excellent service




Review of Chud Air Conditioning & Heating

Great service very thorough and personable

DresherPA19025 40.1525-75.1675

Response from Chud Air Conditioning & Heating:

Joseph, thank you for the 5 star review!


great service




Review of Chud Air Conditioning & Heating

very competent friendly and explained thoroughly

DresherPA19025 40.1525-75.1675

Response from Chud Air Conditioning & Heating:

Joseph, thank you for the kind words and 5 star review! The Chud team appreciates it.


Great service




Review of Chud Air Conditioning & Heating

DresherPA19025 40.13-75.1625

Response from Chud Air Conditioning & Heating:

5 stars, thank you Cathy & Jeff!


Common courtesy problem




Review of Chud Air Conditioning & Heating

My heat is still not working. Was told yesterday that a part need to be ordered. I simply asked to be informed when the part will arrive. We have called twice today to find out when the part needed to fix it will be available and have not yet received an answer. I understand part is not available but simply asking for a courtesy of letting me know when it will be available and I will have heat again.

DresherPA19025 40.13-75.1625

First Time Customer




Review of Chud Air Conditioning & Heating

DresherPA19025 40.1325-75.165

Response from Chud Air Conditioning & Heating:

Thank you for giving Chud a try Mark! Were glad to hear we met your expectations and look forward to working together in the future.


Great service . Knowledgeable guy.




Review of Chud Air Conditioning & Heating

Explained everything well

DresherPA19025 40.135-75.15

Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Jane. Everyone at Chud appreciates it!


Paul T.

Paul T.

Came out today to replace a defrost control board on a Lennox heat pump model #13HPX-042-230-01, serial #5806D25697. I powered the system down and removed the disconnect. I removed the old board and installed a new defrost control board. I made all the proper wiring connections. Once the board was installed I called for heat and tested the system. The system started after a short delay. The supply temp is 117°F and the refrigerant pressures are within normal range. The system is operating properly at this time.

Near Candlebrook Dr, Dresher, PA 19025
Paul A.

Paul A.

Did a preventative maintenance on a gas furnace. Cleaned flame sensor. Did a combustion test and the Ppm was 65 and o2 was 15. Also did an amp check on the inducer motor and blower motor which both met the furnace specs. And I cleaned out the blower mood or housing and the burner rack. Changed out to 14 x 25 x 1 filter. Checked ohms the hot surface igniter. System is operating properly at this point. M#ML180UHO45P24A-55 s#1716H17031

Near Dresher Woods Dr, Dresher, PA 19025
Paul T.

Paul T.

Came out today for a heat pump that froze. Upon arrival I switched the system to heat and observed the system starting normally. I removed the access panels to inspect the system. The evaporator coil’s are clean and in good condition. The blower motor amp draw is 6.4 and the supply temp is at 134°F. The heat pump coils are clean but in fair condition. Many of the fins are bent. The refrigerant pressures are within normal range the heat pump amp draws are 1.98 for the fan and 11.87 for the compressor. I continued to let the system run so that I could observe any issues. The system is operating properly at this time no issues could be found.

Near Candlebrook Dr, Dresher, PA 19025
Keith R.

Keith R.

Performed first floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!

Near Woodside Cir, Dresher, PA 19025
Matthew M.

Matthew M.

Replaced existing 700m humidifier with new aprilaire 700A humidifier and run necessary wiring to new digital humidistat. Condenser has extra conductors to allow for a outdoor temp sensor the digital humidistat requires. Cycled and tested, system working properly at this time.

Near Oakwood Dr, Dresher, PA 19025
Paul T.

Paul T.

Came out today to perform preventative maintenance on a whisper heat Lennox furnace model #g2005/6E-150-7, serial #5899E 30821. Upon arrival I called for heat and the system started right up. I asked the homeowner if they have had any issues and he stated that everything has been working great. I took a combustion analysis test and received the following readings, o2 is 12.6% and the co levels are 6ppm. I powered the system down and removed the access panels. Cleaned out the burners and burner box. Tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Checked all electrical connections to ensure that they are secure and in good condition. I powered the system up and called for heat. The blower motor amp draw is within the manufacture specs. The supply temp is 138°F. The system is operating properly at this time however due to the age of the system chud cannot Guarantee that there won’t be issues in the future. My professiona

Near Jeffrey Dr, Dresher, PA 19025
Paul T.

Paul T.

Came out today for a no heat issue. Upon arrival the thermostat was set to off and the temperature in the home was 70°. I called for heat at the thermostat and went to observe the furnace. The system started without any issues. The homeowner stated this morning there was a lack of air flow at the registers. I checked multiple registers and was getting a decent amount of air flow. The air filter is new and the blower motor amp draw is 3.08. I attempted to recreate the issue by cycling the system on and off but I was unable to recreate the issue I advised the homeowner to monitor the system and if it happens again to call us right away so we can observe what the system is or isn’t doing. The system is operating properly at this time. No charge per office.

Near Pebblewood Ln, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a high efficiency Lennox furnace model #ML195UH090XP48C-58, serial #1716D09301. I powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor and cleaned out the burners and burner box. Replaced the air filter size 16x25x1. Checked the pressure switch for clogs and tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Cleaned out the trap and checked all electrical connections to ensure that they are secure and in good condition. I powered the system up and called for heat. Took a combustion analysis test and received the following readings, o2 is at 12.2% and the co levels are 8ppm. The inducer motor amp draw is at 1.67 and the blower motor amp draw is at 3.6. The supply temp is 118°F. The system is operating properly at this time.

Near Jarrettown Rd, Dresher, PA 19025
Matthew M.

Matthew M.

Completed pm on heater, 401 filter media replacement. Inspected all internal components for proper range and operation. Also completed humidifier maintenance and replaced #35 water panel, tested humidifier for proper operation and drainage. Cycled and tested, all equipment working properly at this time.

Near Beacon Hill Dr, Dresher, PA 19025
Matthew M.

Matthew M.

Completed pm on heating system. Filters are all up to date. Checked all internal components for proper range and function. Cycled and tested, system working properly at this time. Will be collecting 50% of humidifier job which is $582.50. Will collect balance for that job upon completion. Customer currently has a aprilaire 700m that needs to be replaced, and the necessary wire and outdoor sensor run for the digital humidistat.

Near Oakwood Dr, Dresher, PA 19025
Paul A.

Paul A.

Did a maintenance on a older Lennox furnace. Cleaned out the flame sensor and shop vac the entire unit. Clean flame sensor and also cleaned out trap for the high-efficiency drain I made sure everything was properly draining. Customer had already change the filter. Amped up the blower motor and inducer motor which were running as the furnace spec sheet says. Supply air time 133. Customer stated humidifier was leaking. There was nothing I could do about it except recommend her a new humidifier. System is operating properly at this point. M#G26Q3/4-100-6 s#5801E22098 filter size 20x25x1.

Near Timber Ln, Dresher, PA 19025
Paul T.

Paul T.

System #1 located in the basement. Performed preventative maintenance for a high efficiency Coleman furnace model #TG9S120D16MP11B, serial #W1A9543224. I powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor and cleaned out the burners and burner box. Checked the pressure switch to ensure that there are no clogs. Replaced the air filter size 16x25x1. Checked all electrical connections to ensure that they are secure and in good condition. Tested the drain line with several bottles of water to ensure that there are no leaks or clogs. I powered the system back up and called for heat. Took a combustion analysis test and received the following readings, o2 is at 13.1% and the co levels are 9ppm. The inducer motor amp draw is at 2.02 and the blower motor amp draw is at 6.1. The system is operating properly at this time. Performed preventative maintenance for a Bryant heat pump system model #215bna018-A, serial #3212E17176. I powered the s

Near W Bruce Dr, Dresher, PA 19025
Jonathan C.

Jonathan C.

Replaced Bradford white 50 gal, gas, power vent hot water heater and expansion tank. Bled air out of all lines. Cycled and tested, water heater working properly at this time. Performed maintenance on high efficiency gas furnace. Cycled and tested, system working properly at this time.

Near High Point Ave, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a Lennox heat pump, model # XP14-048-230-09, serial #5816LO7724l. I powered the system down and removed the access panels. The evaporator coil’s are clean and in good condition. Tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Checked all electrical connections to ensure that they are secure and in good condition. Performed humidifier service for a Aprilaire model 600. I removed the old #35 water panel and installed a new one. Cleaned out the housing and drain. Tested the system for proper operation and leaks. I powered the system back up and called for heat. The blower motor amp draw is at 4.6. The condenser coil’s are clean and in good condition. The condenser amp draws are 12.6 for the compressor and .96 for the fan. The refrigerant pressures are within normal range for the temperature outside today. The supply temp is at 116°F. The system is operating properly at thi

Near Candlebrook Dr, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a carrier furnace model #58SB0A110E211120, serial #0520A29481. Powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor, cleaned out the burners and burner box. Replaced the air filter size 16x25x4 homeowner supplied. Checked all electrical connections to ensure that they are secure and in good condition. Tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Checked the pressure switches to ensure that they are operating properly. I powered the system up and called for heat. Took a combustion analysis test and received the following readings, o2 is at 8.9% and the co levels are 35ppm. The inducer amp draw is at .67 and the blower motor amp draw is at 7.3. The system is operating properly at this time. No Charge MA.

Near Aidenn Lair Rd, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a high efficiency Lennox furnace. Model #G61MP-60C-091-09, serial #5910J43270. Powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor, cleaned out the burners and burner box. Replaced the air filter size 16x25x1. Checked all electrical connections to ensure that they are secure and in good condition. Checked the pressure switches for any blockages. Cleaned out the trap and tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Performed humidifier service. Removed and replaced the #35 water panel. Cleaned out the tray, housing and drain. I powered the system up and called for heat. Took a combustion analysis test and received the following readings, o2 is 12.4% and the co levels are 17ppm. The inducer amp draw is .30 and the blower motor amp draw is 6.4. Tested the humidifier for proper operation and leaks. Set the humidistat for 35%.

Near Cavan Dr, Dresher, PA 19025
Frank B.

Frank B.

Performed preventative maintenance for standard furnace. Inspected all the electrical components. Confirmed proper high and low voltages. Tested the amp draw for the blower motor and inducer. Both were operating within the manufacturer specs. Replaced the customer supplied filter (16x25x1). Customer no longer gets the humidifier service. Performed a combustion analysis on the furnace. System is operating at 79.9% efficiency with a CO level of 21ppm. System is operating properly at this time. Covered customer condenser as well with customer supplied cover.

Near Winslow Way, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a Lennox furnace model #G50UH-48C-135-05, serial #5803G 89656. I powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor, cleaned out the burners and burner box. Replaced the 401 air filter and checked all electrical connections to ensure that they are secure and in good condition. Performed humidifier service. Removed and replaced the #10 water panel. Cleaned out the tray, housing and drain. Opened the dampener and set the system for 35% humidity. I powered the system up and called for heat. Took a combustion analysis test and received the following readings, o2 is 13.9% and the co levels are 6ppm. Tested the drain line with several bottles of water to ensure that there are no leaks or clogs. The inducer amp draw is at 1.1 and the blower motor amp draw is 4.6. The system is operating properly at this time. Charged quoted price.

Near Jeffrey Dr, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for 2 furnace systems. System #1 located in the basement. Lennox furnace model #el296uh090xv60c-06, serial #5917B15808. I powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor, cleaned out the burners and burner box. Cleaned out the trap and tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Checked all electrical connections to ensure that they are secure and in good condition. Replaced the air filter size 16x25x1. I powered the system up and called for heat . I took a combustion analysis test and received the following readings, o2 is at 12.5% and the co levels are at 12ppm. The inducer motor amp draw is .35 and the blower motor amp draw is at 8.1. System #2 located in the attic. Lennox furnace model # G60UH-36B-090-07, serial #5906J31417. Powered the system down and removed the access panels. Removed and cleaned carbon carbon off

Near Catlin Way, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a Lennox furnace model #SL280UH090V60C-03, serial # 5914C37664. Powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor, cleaned out the burners and burner box. Replaced the air filter size 24x24x1 supplied by the homeowner. Checked all electrical connections to ensure that they are secure and in good condition. Checked to ensure that the pressure switch tubing was clear of any debris. Tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Performed humidifier service on an aprilaire humidifier. I removed the old water panel and cleaned out the tray, housing and drain. I installed a new #35 water panel. I powered the system back up and called for heat. Took a combustion analysis test and got the following readings, o2 is at 13% and the co levels are 9ppm. Tested the humidifier for proper operation and leaks. The inducer motor amp draw is

Near Castlewood Dr, Dresher, PA 19025
Paul T.

Paul T.

Install new control board on a Lennox furnace, M# ML180UH090P36B-53 S# 1714H13011. Once installed check the system for proper operation and possibly do a maintenance. The part is covered under warranty. Maintenance and labor charges will be accessed for this repair. 10-7-22-PT- installed a new control board for a Lennox furnace. Removed the old board and installed the new on wire for wire. After the repair was made I tested the system and observed it starting normally. I powered down the system and performed preventative maintenance. Lennox furnace model #ML180UH090P36B-53, serial #1714H13011. I removed and cleaned carbon off of the flame sensor. Cleaned out the burners and burner box. Checked to ensure that the pressure switches were free of any debris. Checked all electrical connections to ensure that they are secure and in good condition. The air filter size 16x25x1 was recently replaced. I powered the system On and called for heat. Took a combustion analysis test and received

Near Jeffrey Dr, Dresher, PA 19025
Frank B.

Frank B.

Performed preventative maintenance for 2 gas furnaces. Main house system is in the basement and the new addition system is in the attic in the master bedroom. Inspected all the electrical components. Confirmed proper high and low voltage. Cleaned the burners, burner compartments, inducer ports and flame sensors. Inspected all safety devices for proper operation. Performed a combustion analysis on both system. The main house system is operating at 80.2% efficiency with a CO level of 29ppm. The attic system is operating at 82.3% efficiency with a CO level of 12ppm. Filter for basement #201 is due in the spring and I replaced the customer supplied 16x25x1 filter for attic system. Both systems are operating properly at this time.

Near Derry Dr, Dresher, PA 19025
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time.system is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!

Near Candlebrook Dr, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a Lennox system model #EL180UH110E60C-02, serial #5917L13328. Powered down the system and removed the access panels. Removed and cleaned carbon off of the flame sensor, cleaned out the burners and burner box. Replaced the 16x25x5 air filter (homeowner supplied). Checked all electrical connections to ensure that they are secure and in good condition. Performed humidifier service. Removed the old water panel and installed a new #35 water panel. Cleaned out the housing and drain line. Tested the system for leaks. Powered the system back up and called for heat. Performed a combustion analysis test and received the following readings, o2 was at 11%, co is at 26ppm. The inducer amp draw and blower amp draw is within normal range. Both systems are operating properly at this time.

Near Nicole Dr, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a Lennox furnace model #SL280UH090V36B-04, serial #5919F01695. I powered the system down and removed and cleaned carbon off the flame sensor. Cleaned out the burners and burner box. Checked all electrical components to ensure that they are secure and in good condition. Replaced the air filter 20x25x6 supplied by the homeowner. Powered the system back up and called for heat. Took a combustion analysis test and got the following readings o2 is at 11% and the co reading is 11ppm. The inducer motor and blower motor amp draws are within normal range. The supply temp is at 108°F. The homeowner stated that they had a slight flood and wanted me to check for damage. There are no signs of water damage. The water didn’t get high enough to damage anything. The system is operating properly at this time.

Near Twining Rd, Dresher, PA 19025
  • HomeAdvisor Top Rated Service
  • HomeAdvisor Elite Service Award - Chud Air-Conditioning, Heating, Refrigeration Co., Inc.
100% Customer Satisfaction Guaranteed
Schedule Service Today
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Please Upload Your Photos
Contact and Service Location...
You and Your Service Location
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon
Back Next