Chud has provided air conditioning, heating, water heater, air quality and duct cleaning services to the residents of Dresher, PA and the surrounding areas since 1970! We're committed to providing first class air conditioning service to all of our clients.

How much does it cost to replace an HVAC system near Dresher?

The cost to replace an HVAC system near Dresher and other areas of Greater Philadelphia averages $7,000, with a range of $5,000 to $10,000

Some of the primary factors that can influence the price are:

  • Size of the house (and size of the system required).
  • The complexity of the installation. For example, whether the new unit also requires new ductwork.
  • Brand and type of system. High-end brands will usually cost more.

Dresher homeowners with questions about their HVAC system can contact the expert team at Chud today for trusted advice.

How much does HVAC repair usually cost near Dresher?

An HVAC repair near Dresher or other areas of Philadelphia usually costs between $150 and $300. At the same time, note that repair or replacement costs for major components like coils can be much more costly.

The total cost of the problem depends on factors like:

  • The time it takes to complete the repair.
  • Prices of any new components or parts needed.
  • The system’s make, model and age.

Most companies will charge a diagnosis fee to have an HVAC tech come out and look at the problem. 

If you see signs that the HVAC system in your Dresher home may be having issues, contact the trusted service team at Chud, and we can send out a technician right away.

Can an air conditioning system leak be fixed?

In many cases, no, an air conditioning refrigerant leak cannot be fixed, at least not as a long-term solution. Usually, a refrigerant leak is discovered when a system doesn’t seem to be cooling well and a homeowner calls an HVAC technician to test the system. 

Leaks are usually caused by a multitude of pinhole-sized leaks in a coil, especially in older systems. An HVAC tech can sometimes try to charge the refrigerant or seal the coils, but these fixes often don’t last long. Sometimes, a homeowner will have to weigh the pros and cons of repairing or replacing the system.

It’s essential to work with an HVAC company that you trust if you are considering a major repair like a refrigerant leak. Homeowners in Dresher, PA, can contact the local experts at Chud for HVAC repairs, maintenance and replacement.

We're the AC experts. But don't take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby Dresher, PA heating and air company that specializes in air quality and duct cleaning.

Local Reviews
for Dresher, PA

Chud Air Conditioning & Heating Rated 4.9 out of 5 stars based on 39 customer reviews


Map of Dresher, PA

Great Service




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you Francis & Miriam!


Map of Dresher, PA

Chud is efficient




Review of Chud Air Conditioning & Heating

Been keeping up the maintenance for years and have had no issues. Definitely worth the piece of mind.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Marc & Shelley, everyone at Chud appreciates it!


Map of Dresher, PA

Great Service




Review of Chud Air Conditioning & Heating

Sebastian was competent & personable.


Response from Chud Air Conditioning & Heating:

Charles & Joanne, thank you for the kind words and 5 star review!


Map of Dresher, PA

Great service, on time, professional, neat




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Jeff & Jane.


Map of Dresher, PA

Home Reno cleaning




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

We always strive for 5, please give us a call at 215-659-4343 to let us know what we could have done to get that 5th star.


Map of Dresher, PA

Great Service




Review of Chud Air Conditioning & Heating

Frank is very professional & not only expert at his profession, but caring & kind in his demeanor.


Response from Chud Air Conditioning & Heating:

Thank you for the kind words and 5 star review! The Chud team appreciates it.


Map of Dresher, PA

Excellent service




Review of Chud Air Conditioning & Heating

Great service very thorough and personable


Response from Chud Air Conditioning & Heating:

Joseph, thank you for the 5 star review!


Map of Dresher, PA

great service




Review of Chud Air Conditioning & Heating

very competent friendly and explained thoroughly


Response from Chud Air Conditioning & Heating:

Joseph, thank you for the kind words and 5 star review! The Chud team appreciates it.


Map of Dresher, PA

Great service




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you Cathy & Jeff!


Map of Dresher, PA

Common courtesy problem




Review of Chud Air Conditioning & Heating

My heat is still not working. Was told yesterday that a part need to be ordered. I simply asked to be informed when the part will arrive. We have called twice today to find out when the part needed to fix it will be available and have not yet received an answer. I understand part is not available but simply asking for a courtesy of letting me know when it will be available and I will have heat again.


First Time Customer




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

Thank you for giving Chud a try Mark! Were glad to hear we met your expectations and look forward to working together in the future.


Great service . Knowledgeable guy.




Review of Chud Air Conditioning & Heating

Explained everything well


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Jane. Everyone at Chud appreciates it!


Fall Maintenance




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you Francis & Miriam!


Annual heater service




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Ruth! Everyone at Chud appreciates it.


Paul - technician




Review of Chud Air Conditioning & Heating

He was great! Thanks


Response from Chud Air Conditioning & Heating:

The Chud team loves to see 5 star reviews! Thank you William.


Great service




Review of Chud Air Conditioning & Heating

The technician was Very knowledgeable and thorough, and personable. Will definitely use again!


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Mary Ellen!


Extraordinary service!




Review of Chud Air Conditioning & Heating

Frank is a knowledgeable professional who always goes above & beyond for the customer. He is extraordinary!


Response from Chud Air Conditioning & Heating:

Charles & Joanne we’ll make sure to pass your kind words along to Frank, who we know will be delighted to read your comments.


Great experience




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Aimee.


Excellent Service




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you for the 5 star review!


Heating system




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

Thank you Peter & Jackie for the 5 star review!


Great job




Review of Chud Air Conditioning & Heating

The men were all nice, professional, and did a great job


Response from Chud Air Conditioning & Heating:

Jane, thank you for leaving Chud a 5 star review!


504 Dresher Woods Dr.




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

Jill, thank you for leaving Chud a 5 star review!


Great service from Paul T.




Review of Chud Air Conditioning & Heating

Paul was professional & knowledgeable & helpful in describing the issue.


Response from Chud Air Conditioning & Heating:

Charles & Joanne, thank you for sharing you experience, everyone at Chud appreciates it!


Quick and Easy




Review of Chud Air Conditioning & Heating

Paul came right on time and did a great job in the amount of time promised. What more could you ask for?


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Justin, everyone at Chud appreciates it!


Frank Breen




Review of Chud Air Conditioning & Heating

Great service as always with Frank.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Charles & Joanne. It truly means a lot to the Chud team!


Paul T.

Paul T.

Performed preventative maintenance for a Lennox system model #SL280UH110V60C-03, serial #5911F00896. The evaporator coil’s are clean and in good condition. Tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. The Aprilaire filter was changed in the fall. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. The blower motor amp draw is within normal range. The temperature split is at a 20. The condenser coil’s are clean and in good condition. The condenser amp draws are .83 for the fan and 15.4 for the compressor. The refrigerant pressures are within normal range for the temperature outside today. The system is operating properly at this time.

Near Timber Ln, Dresher, PA 19025
Paul T.

Paul T.

Came out today for a no ac call. Upon inspection I found that the thermostat was calling for ac but the condenser was not operating. I checked the voltage at the condenser and noticed that there was no control voltage. I traced it back to the pressures switch. I went to reset the pressure switch and noticed that the rubber on top of the button was missing and so as the entire button. Recommend replacing the high pressure switch so the system can operate properly. The system is bypassed at this time. Chud will have to reach out to the homeowner with a repair quote. Lennox system model #xc14-048-230-01, serial #5809d13707.

Near Oakwood Dr, Dresher, PA 19025
Keith R.

Keith R.

Performed a 2nd floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business! Customer paid in advance.

Near Dresher Woods Dr, Dresher, PA 19025
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!

Near Jeffrey Dr, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a York furnace model #p3urd12n07501a, serial #emfm386945. Removed and cleaned carbon off of the flame sensor. Cleaned out the burners and burner box. Replaced the air filter size 16x25x1. Observed the system starting normally and took a combustion analysis test. O2 is at 8.2%, co is 8 ppm and the system is operating at 88% efficiency. The inducer motor amp draw is at .36. The furnace is operating properly at this time. Performed preventative maintenance for a York ac system model #h2ra030806a, serial #eafm017270. The evaporator coil’s are clean and in good condition. Tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. The air filter was replaced. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. The blower motor amp draw is within normal range. The temperature split is at a 18. The condenser is in rough condition but is stil

Near Brookdale Ct, Dresher, PA 19025
Frank B.

Frank B.

Performed preventative maintenance for air conditioning system per the repair agreement. Inspected all the electrical components. Confirmed proper high and low voltages. Tested the temperature split between the supply and return. System is operating at a 20° differential on a 88° day. Replaced the standard air filter 20x25x1. Tested the amp draw for the blower, compressor and fan motor. All were operating within the manufacturer specs. Dumped out the condensate pump of sludge buildup in the reservoir. Made sure drain piping was clear and vinyl tubing from the pump. Drain and pump are operating properly at this time. System is operating properly at this time. No charge today due to prepaid repair agreement.

Near Pebblewood Ln, Dresher, PA 19025
Paul A.

Paul A.

Performed a thorough system analysis on the newly installed Trane HVAC system. Static pressure readings were within range. The temperature split initially was at 18 degrees. We lowered the blower speed to tap #4 which will dehumidify the house better. To complete the process we checked the subcooling. We discovered there was no subcooling at all. We ended up charging the system with an additional 2lbs 3oz of 410a refrigerant. The temperature split is still at 18 degrees, however the system is now fully commissioned and will operate to peak performance. Steve, a Trane representative was present during the process and provided support and guidance for fine tuning the system. N/C, WARRANTY. Trane M#S8X2B080M4PSCAA, S#22092P4XHG. MERV 11 (16x25x4) spring and fall.

Near Bantry Dr, Dresher, PA 19025
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!

Near Nicole Dr, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a Lennox system model #el180uh110e60c-02, serial #5917l13328. The evaporator coil’s are clean and in good condition. Tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. The homeowner changes the filter regularly and will continue to do so. Filter size Merv11 16x25x5. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. Blower motor amp draw is at a 4.6. The temperature split is at a 20. The condenser coil’s are clean and in good condition. The condenser amp draws are .58 for the fan and 9.1 for the compressor. The refrigerant pressures are 131/288. These are normal readings for the temperature outside today. The system is operating properly at this time.

Near Nicole Dr, Dresher, PA 19025
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend air duct cleaning every 3-4 years. Thank you for your business!

Near Beacon Hill Dr, Dresher, PA 19025
Sebastian R.

Sebastian R.

Installed and replaced PAK.

Near Oakwood Dr, Dresher, PA 19025
Sebastian R.

Sebastian R.

Performed preventative maintenance on Carrier AC system. Customer replaced 20x25x1 air filter prior to us coming out. Checked evaporator coil pan and condensate pump for proper drainage. Temperature split is at 20° with a supply air temperature of 51°. This unit has the proper refrigerant charge. Compressor- 6.8 RLA Condenser fan motor- 0.8 FLA . Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the season. Carrier condenser- S#50727U43F M#2TTR2042B1000AA Filter size- 20x25x1

Near Aidenn Lair Rd, Dresher, PA 19025
Paul A.

Paul A.

Adjusted cooling blower speed to speed setting #6 which is ideal to remove more humidity from the home and provide a higher level of comfort to the homeowner. We spoke with Trane technical support department and determined that this particular furnace, S8X2 is not adjustable for the fan speed in the “fan only” setting. N/C, WARRANTY for this portion of work. We also installed a Reme Halo LED whole house air purifier. We wired the device direct to a transformer as recommended by the manufacturer. We verified the device is receiving power and working properly. Special discount price with new Trane system. ****Halo LED S#S3VRLED1443, and the model# REME-LED EPA establishment #067400-FL-001. Installed 5/26/22.**** Trane M#4TTX6036J1000CA, S#221726655F. Filter size-MERV 11(16x25x4)

Near Bantry Dr, Dresher, PA 19025
Sebastian R.

Sebastian R.

Performed preventative maintenance on Lennox AC system. Replaced 24x24x1 Air filter provided by the customer. Tested evaporator coil pan and condensate line for proper drainage. Temperature split is at 20° with a supply air temperature of 53°. This unit has the proper refrigerant charge. Compressor- 5.3 RLA Condenser fan motor- 1.0 FLA . Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the upcoming season. Lennox condenser- S#5814C12438 M#XC21-060-230-11 Filter size- 24x24x1

Near Castlewood Dr, Dresher, PA 19025
Sebastian R.

Sebastian R.

Performed preventative maintenance on Lennox AC system. Replaced 16x25x1 air filter provided by customer. Tested condensate line and evaporator coil pan for proper drainage. Temperature split is at 20° with a supply air temperature of 52°. This unit has has an accurate refrigerant charge. Compressor-5.9 RLA Condenser fan motor-0.7 FLA . Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the upcoming season.

Near Brookdale Ct, Dresher, PA 19025
Sebastian R.

Sebastian R.

Came out for no AC call. Upon arrival unit is operating properly but does not have the right temperature split. There is 62° Supply air coming out of the unit and 72° Return air. This is only a 10° temperature split and is why the unit is not meeting the set temperature on the thermostat. Connor has been informed of the status of their system that it is not a broken unit but is not going to keep up with their home for the summer time. It is a 15+ year old R-22 system and they are being recommended to upgrade to new equipment. Chud has taken photos of the unit and is referring the customer over to our sales department to get an estimate on new equipment. Lennox condenser model and serial n/a

Near Glenburnie Ln, Dresher, PA 19025
Matthew M.

Matthew M.

Installed new Trane equipment. Project included new pad whip an disconnect. Adapted to supply an return added new 25x16x4 filter rack adapted to gas line added new shut off valve, adapted to high voltage added new switch receptacle, installed new condensate pump with new vynl. Adapted to low voltage, installed new thermostat. System is tested an working properly at this point.

Near Bantry Dr, Dresher, PA 19025
Sebastian R.

Sebastian R.

Upon arrival AC was not working due to a tripped breaker for the condenser. Flipped breaker back on , unit is now operating and able to do the maintenance. Performed preventative maintenance on Lennox AC system. Wrong filter size in system will have to come back to replace filter. Tested evaporator coil pan and condensate pump for proper drainage. Temperature split is at 20° with a supply air temperature of 52°. This unit has an accurate refrigerant charge. Compressor- 8.6 RLA Condenser fan motor- 1.0 FLA. Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the summer.

Near Oakwood Dr, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a Lennox system. The evaporator coil’s are clean and in good condition. Tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. The homeowner recently replaced the the air filter (Merv11 16x25x6). Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. I observed the system starting normally. The blower motor amp draw is at 1.3. The temperature split is at a 20. The condenser coil’s are clean and in good condition. The condenser amp draws are .43 for the fan and 4.7 for the compressor. The refrigerant pressures are 111/223. These are normal readings for 410-A refrigerant with an ambient temperature of 60°. The system is operating properly at this time.

Near Twining Rd, Dresher, PA 19025
Frank B.

Frank B.

Performed preventative maintenance for air conditioning system. Inspected all the electrical components. Customer replaced the air filter recently. Confirmed proper high and low voltages. Inspected the drain pipe and condensate pump. Drain is clear and pump is working properly. Tested the temperature split between the supply and return. System is operating at a 20° Differential on a 68° day. Tested the amp draw for the blower, compressor and fan motor. All were operating within the manufacturer specs. Shut down the bypass humidifier for the season. System is operating properly at this time and ready for the summer season. Customer receives a senior discount per note in account.

Near Cavan Dr, Dresher, PA 19025
Sebastian R.

Sebastian R.

Performed preventative maintenance on Lennox AC system. Replaced 16x25x1 air filter provided by the customer. Tested evaporator coil pan for proper drainage. Temperature split is at 19° with a supply air temperature of 51°. This unit has the proper refrigerant charge. Compressor- 2.8 RLA Condenser- 0.5 FLA . Both of these readings are within the amperage rating for this unit. System is operating properly properly at this time and is ready for the upcoming season.

Near Winslow Way, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a Coleman system. Model #tg8s100c16mp11b, serial #w1m6198459. The evaporator coil’s are clean and in good condition. Tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Replaced the air filter 16x25x1. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. I observed the system starting normally. The blower motor amp draw is 1.7. The temperature split is at a 19. The condenser coils are clean and in good condition. The condenser amp draws are .67 for the fan and 7.3 for the compressor. The refrigerant pressures are 102/216. These are normal readings for 410-A refrigerant with an ambient temperature of 60°. The system is operating properly at this time and is ready for the air conditioning season.

Near Tralee Dr, Dresher, PA 19025
Paul T.

Paul T.

Performed preventative maintenance for a Lennox heat pump system. The evaporator coil’s are clean and in good condition. Tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Replaced the air filter Merv11 20x25x5. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. I observed the system starting normally. The blower motor amp draw is 4.6. The temperature split is at a 20. The condenser coil’s are clean and in good condition. The condenser amp draws are 1.1 for the fan and 8.2 for the compressor. The refrigerant pressures are 91/195. These are normal readings for 410-A refrigerant with an ambient temperature of 58°. The system is operating properly at this time and is ready for the air conditioning season.

Near Candlebrook Dr, Dresher, PA 19025
Sebastian R.

Sebastian R.

Performed preventative maintenance on Lennox AC system. Replaced 16x25x1 air filter. Tested condensate pump and evaporator coil pan for proper drainage. Temperature split is at 21° with a supply air temperature of 45°. This unit has an accurate refrigerant charge. Compressor- 6.2 RLA Condenser fan motor- 1.2 FLA Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the season. Lennox Condenser- S#5816F18619 M#XC14-047-230-04 Filter size- 16x25x1

Near Jarrettown Rd, Dresher, PA 19025
Sebastian R.

Sebastian R.

Performed preventative maintenance on Coleman AC system. Replaced 16x25x1 air filter provided by customer. Tested evaporator coil pan and condensate pump for proper drainage. Temperature split is at 21° with a supply air temperature of 42°. Thus unit has an accurate refrigerant charge. Compressor- 8.5 RLA Condenser fan motor- 0.7 . Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the season. Coleman condenser- S#W1N6258424 M#TC3B4821SA Filter size- 16x25x1

Near Woodland Rd, Dresher, PA 19025
  • HomeAdvisor Top Rated Service
  • HomeAdvisor Elite Service Award - Chud Air-Conditioning, Heating, Refrigeration Co., Inc.
100% Customer Satisfaction Guaranteed
Schedule Service Today
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Please Upload Your Photos
Contact and Service Location...
You and Your Service Location
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon
Back Next