Chud has provided air conditioning, heating, water heater, air quality and duct cleaning services to the residents of Levittown, PA and the surrounding areas since 1970! We’re committed to providing first class air conditioning service to all of our clients.
We’re the AC experts. But don’t take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby Levittown, PA heating and air company that specializes in air quality and duct cleaning.
Local Reviews
for Levittown, PA
Our Reviews by City
Paul was very friendly and informative
Cathy - Levittown, PA
Response from Chud Air Conditioning & Heating:
Thank you for the kind words and 5 star review Cathy!

Matthew M.
Completed electric water heater installation. Water heater is 50 gallon electric water heater. Adapted to existing plumbing, electrical, pressure relief run off. Added new cold side shutoff valve, st5 expansion tank, and a watch dog water alarm. Goliath pan is installed under water heater, and sensor from water alarm runs into pan. Replaced piece of dryer vent that was damaged with new flexible dryer duct. Cycled and tested water heater and dryer, both are working properly at this time. Customer paid balance in advance.

Keith R.
Performed dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Properly installed bird guard with masonry anchors. Thank you for your business!

Paul T.
Performed preventative maintenance for a Heil heat pump model. I observed the system starting normally. The supply temp is at 125°F. Amp draw for the blower motor is at 1.5. I observed the system shut down normally once it reached the desired temperature. All electrical components are intact and operating properly. Blower wheel is clean. Evaporator coil's are dirty due to the air filter not being changed. Performed evaporator coil cleaning. Replaced the air filter size 20x20x1. The refrigerant pressures are within normal range. The amp draws for the fan and compressor are within normal range. The condenser coils are clean..

Keith R.
We installed a bird cage per customers request, dryer vent is flowing properly. We would need about 25' of 4" pipe and possibly four 90 degree pipes. Bird cage is properly installed.

Paul T.
Performed preventative maintenance for a Goodman heat pump. Observed the system starting normally. Replaced the air filter. Blower motor amps are within range. Evaporator coils and blower wheel are clean. Heat coils are in good condition. Refrigerant pressures are within normal range. Amp draws are 6.2 for the compressor and .7 for the fan. Checked all electrical components needed for heating. The system is operating properly at this time.

Paul A.