Chud has provided air conditioning, heating, water heater, air quality and duct cleaning services to the residents of Wyndmoor, PA and the surrounding areas since 1970! We’re committed to providing first class air conditioning service to all of our clients.

We’re the AC experts. But don’t take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby Wyndmoor, PA heating and air company that specializes in air quality and duct cleaning.

Local Reviews
for Wyndmoor, PA

Chud Air Conditioning & Heating Rated 4.6 out of 5 stars based on 7 customer reviews
Mobile Tools for Contractors and Service Professionals Powered by Nearby Now


Map of Wyndmoor, PA

Great service




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

5 stars, thank you Gavin and Brianna!


Map of Wyndmoor, PA

Did a great job




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Paul.


Map of Wyndmoor, PA

I trust the tech - will do what he says.




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Tom, everyone at Chud appreciates it!


Map of Wyndmoor, PA

Great Service!!!




Review of Chud Air Conditioning & Heating

Waiting for Parts.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Bernard!


Map of Wyndmoor, PA

Your technicians, excellent work




Review of Chud Air Conditioning & Heating

The sales man, needs to be more honest, about the prices, where I fear Youwill go out of business, If he does it and tries to work with your customers, more honest and fairly with the price


Response from Chud Air Conditioning & Heating:

Hi Mr. Rhinehart. Thank you for allowing us to be of service to you recently. We are deeply sorry we did not meet your expectations. We strive to provide 5 star service and 100% customer satisfaction. Please give us a call at 215-659-4343 so we can discuss your concerns over the phone and provide a solution to you.


Map of Wyndmoor, PA

Excellent




Review of Chud Air Conditioning & Heating

Excellent


Response from Chud Air Conditioning & Heating:

5 stars, thanks William!


Map of Wyndmoor, PA

Dependable and excellent service




Review of Chud Air Conditioning & Heating


Response from Chud Air Conditioning & Heating:

Thank you for the review Maureen, we're so glad you can depend on us!


Paul A.

Paul A.

Found low water pressure again on boiler. We made a previous recommendation and this repair must be completed for us to continue service on this appliance. The low water cutoff prevented the boiler from operating. Quoted customer for repair, and we will schedule to return. Temporarily restored heat today for homeowner.

Near E Willow Grove Ave, Wyndmoor, PA 19038
Paul A.

Paul A.

Performed preventative maintenance on Coleman gas furnace. There was a "no heat" issue on arrival due to a blocked 16x25x1 air filter. Replaced the air filter and removed a few items from return boot. Combustion analysis performed-CO PPM 3, 359.6 stack temp, operating at 86.7% efficiency. Cleaned sensors and inspected burners/burner compartment. System is currently operating properly. Homeowner is going to have air duct cleaning performed.

Near Wainwright Rd, Wyndmoor, PA 19038
Anthony  C.

Anthony C.

Replace hot water heater. Customer does not have email so he will give us a call. Replacement water heater and photos are left on estimate to see more info on the replacement.

Near Childs Rd, Wyndmoor, PA 19038
Matthew M.

Matthew M.

Damper motor was working intermittently when working on boiler, replaced motor and boiler continued to work intermittently. Diagnosed unnecessary peanut relay to be defective causing power to cut in and out. Removed peanut relay and wire nutted wires together to complete circuit. Boiler is now working properly, customer requested they keep original damper motor in place and not have it replaced.

Near Patton Rd, Wyndmoor, PA 19038
Paul T.

Paul T.

Came out today for a Weil-McLain boiler system not operating. Upon inspection I found that the system receives a call for heat and the circulator pump turns on but the dampener does not open. I checked to ensure that the dampener was receiving proper voltage and it is receiving 26volts. My recommendation is to replace the dampener motor. We will have to look up the price of the part, order it and schedule a return visit to install the new dampener motor. See estimate for reference photos.

Near Patton Rd, Wyndmoor, PA 19038
Anthony  C.

Anthony C.

Performed preventative maintenance on Coleman Gas Furnace. Replaced 16x25x1 air filter. Cleaned and inspected burners, flame sensor and blower compartment. Completed a combustion analysis and the CO PPM was 2. System is working properly at this time and is ready for the season!

Near Childs Rd, Wyndmoor, PA 19038
Frank B.

Frank B.

Returned to drain, refill and purge after adding boiler flush solvent about 2 weeks ago. Customer mentioned that since the drain and flush was added the room has been heating very well. After refilling the boiler with fresh water I added a small dose of descaler to prevent buildup or blockage in the future. System is operating properly at this time. No charge today due to customer prepaying for job last visit.

Near Ardmore Ave, Wyndmoor, PA 19038
Frank B.

Frank B.

Came out to drain the system add a cleaning solution and fill the system back up. The system will have to run for 2 weeks. We would then come back drain the system again and refill it with fresh water and depending on condition maybe add some more solution that can stay in there to prevent buildup. This is not guaranteed to fix the issue with the 2 radiators on the second floor but inspected the condition and feeling the pipe get hot to those radiators before I left is a major improvement from not having any warmth. System is operating properly at this time. Office will call to schedule return visit in 2 weeks.

Near Ardmore Ave, Wyndmoor, PA 19038
Keith R.

Keith R.

Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years. Thank you for your business!

Near Firethorne Ln, Wyndmoor, PA 19038
Frank B.

Frank B.

Performed preventative maintenance on (2) systems. Heat pump system serves the addition. Checked electric heat, inspected blower compartment and verified proper amperage readings. Tested the temperature split for heat pump to make sure it’s in range per the manufacturer. Customer supplies custom filter for this system which I installed for them. Performed preventative maintenance on Lennox gas furnace. Cleaned the burners, flame sensor and burner compartment. Replaced the standard air filter 16x25x1. Performed a combustion analysis on the furnace. System is operating at 96.2% efficiency with a CO level of 19ppm. verified proper gas pressure and temperature rise per manufacturer specifications. Cleared hoses for cold end collector box, pressure switches and inducer. Both systems are operating properly at this time. No charge today due to Customer having a prepaid maintenance agreement.

Near Gate Rd, Wyndmoor, PA 19038
Paul A.

Paul A.

Inspected Crown boiler with reported water leak. No active leak at this time. Potentially may have leaked from a maid-o-mist #67. Based on water marks, there is the potential that water may have leaked from a maid-o-mist #67, however we can not say with 100% certainty since there is no water leaking at this moment. We will leave an optional repair estimate.

Near Lea Cir, Wyndmoor, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Weil-McLain boiler. Observed the system starting normally. Took a combustion analysis test and got the following readings, o2 is 10%, coils at 13ppm and the system is operating at 80% efficiency. Observed the system shut down normally. Pressure is set for 16 psi. Limit is set for 180F. Circulator pump is operating properly. Dampener is operating properly. Auto fill is operating properly. Removed and cleaned burners and burner box. System has 2 radiators on the second floor that are not getting hot. I bled both radiators but still have no heat . There may be a blockage of corrosion in the system. The only thing we could do per PA is drain the system add a cleaning solution and fill the system back up. The system will have to run for 2 weeks. We would then come back drain the system again and refill it with fresh water. This is not guaranteed to fix the issue.

Near Ardmore Ave, Wyndmoor, PA 19038
Paul A.

Paul A.

1. Preventative maintenance on Carrier high efficiency gas furnace. Combustion analysis CO PPM 4. Replaced air filter. Homeowner declined service for the Aprilaire 600M bypass humidifier, he replaced the #35 water panel already. Draft inducer amperage is high, explained why this is important and that the potential for failure could occur. Cleaned flame sensor, inspected burners and indoor blower. Furnace is operating properly and ready for the season. 2. Preventative maintenance on Weil McLain draft induced gas boiler. Standard efficiency (80%) Verified proper water pressure. This "GV-3" that is vented with 3" stainless steel (AL29-4C) and trapped for condensation. Using a 3" PVC air intake. Combustion analysis CO PPM 12. Boiler heats a "studio/garage" area only in the home. Verified proper operation for single zone system. Ready for the season.

Near Carlisle Rd, Wyndmoor, PA 19038
Frank B.

Frank B.

Performed preventative maintenance for high efficiency furnace. Inspected all the electrical components. Customer replaced the standard air filter (20x24x1). Made sure all tubing to the pressure switches, inducer and collector box were clear. Tested the amp draw from the blower and inducer. Both were operating within the manufacturer specs. Cleaned the flame sensor, burners and burner compartment. Performed a combustion analysis on the furnace. System is operating at 93% efficiency with a CO level of 14ppm. System is operating properly at this time. Customer is interested in the duct cleaning and wants to schedule an appointment. I marked the estimate as sold since customer wants to move forward.

Near E Gravers Ln, Wyndmoor, PA 19038
Jonathan C.

Jonathan C.

Performed heating maintenance. Changed 16x25x1 filter. Furnace is only a year old. Cleaned flame sensing rod. No need for combustion analysis. Tested and cycled furnace, furnace is operating properly at this time.

Near Laurel Ln, Wyndmoor, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Lennox heat pump. Observed the system starting normally. Blower motor amp draw is 2.4. Observed the system shutting down normally. Heat kit coils are in good condition. Checked to ensure that there is no buildup on the evaporator coil. Checked the drain line and drain pan. Checked to ensure that the condensate pump is operating properly. Checked all electrical components needed for heating. Replaced the air filter 20x25x1. Checked the condenser for buildup. The refrigerant pressures are within normal range. The amp draws are 7.2 for the compressor and 1.3 for the fan.

Near Duveen Dr, Wyndmoor, PA 19038
Paul A.

Paul A.

Performed preventative maintenance on gas boiler. Checked/cleaned burners and burner compartment, verified proper water pressure and verified limit set point. Verified operation of circulator pumps, checked expansion tank, auto fill, spiral vent. System is operating properly.

Near Patton Rd, Wyndmoor, PA 19038
Jonathan C.

Jonathan C.

Performed heating maintenance on furnace. Changed filter and water panel on humidifier. Checked operation of condensate pump because furnaces condenses and for humidifier. Pump is operating properly at this time. Cleaned flame sensing rod. Performed combustion analysis and furnace is venting properly with no carbon monoxide. Tested and cycled furnace and humidifier and they are both operating properly at this time. Recommended duct cleaning and dryer vent cleaning.

Near Wyndmoor Ave, Wyndmoor, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Bryant boiler. Observed the system starting normally. Upon arrival the water pressure was at 5 psi. I filled the boiler until the pressure reached 14psi. Took a combustion analysis test and got the following readings, o2 is at 15%, co is 6ppm and the system is operating at 80% efficiency. Limit is set for 180. Circulator pump is operating properly. All the valves are in good condition. Expansion tank is in good condition. Observed the system shutting down normally. Removed and cleaned the burners and burner box. The system is operating properly at this time.

Near E Pleasant Ave, Wyndmoor, PA 19038
Frank B.

Frank B.

Performed preventative maintenance for gas furnace. Replaced the customer supplied filter. Filter should be replaced once every 30-90 days. Cleaned the burners, flame sensor and burner compartment. Inspected all the electrical components. Found heavy rust on the burners and within the compartment. This is due to moisture from the flue. Performed a combustion analysis on the furnace. System is operating at 80.9% efficiency with a CO level of 30ppm. System had a temperature rise of 51°. Confirmed proper high and low voltages. Customer would like to update equipment in the near future. I agree it should be updated due to age and condition even though it is running in a safe manor at this time. Forwarding customer info to Scott McHale our comfort Advisor. System is operating at its maximum performance for its age at this time.

Near Hull Dr, Wyndmoor, PA 19038
Paul T.

Paul T.

Found failed condenser fan motor. This is a quote to replace the fan motor, blade and capacitor with labor. Replace the parts and complete the heater and air conditioning maintenance for this unit only. Maintenance has been completed for the other system. Customer replaces Merv filter. Parts are already ordered through Lennox under

Near Biddlewoods Rd, Wyndmoor, PA 19038
Frank B.

Frank B.

Customer called to have preventative maintenance done on 2 full systems (2 - AC maintenances and 2 heater maintenances) as well as the air conditioning system for the left side of the house is not working.

Near Biddlewoods Rd, Wyndmoor, PA 19038
Frank B.

Frank B.

Customer called for mini split not operating properly. Upon inspection I found the indoor evaporator starting to ice up which is a sign cooling issue or low refrigerant. Hooked my gauges up to the system and found it to be low on refrigerant. Added 2lbs of 410A refrigerant. System pressures were 127/328 and a temperature split of 20°.

Near Patton Rd, Wyndmoor, PA 19038
Keith R.

Keith R.

Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years.

Near Laurel Ln, Wyndmoor, PA 19038
Paul T.

Paul T.

Replace blower motor. System had error code for blower motor seizure and failure. This is due to the power outage. Removed old blower motor and board and installed new components. The system is operating properly at this time.

Near Firethorne Ln, Wyndmoor, PA 19038
100% Customer Satisfaction Guaranteed
Schedule Service Today
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Please Upload Your Photos
Contact and Service Location...
You and Your Service Location
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon
Back Next